Welcome to BNA company!

No. 1688, Gaoke East Road,Shanghai, China.

Call us anytime

0086-21-58386256

Opeening Time

Mon-Sat: 8.30-18.00

Is a tile backsplash required behind a gas range top? - Houzz

Tile applied directly to a wood framed wall or gypsum board is NOT an approved method of protecting the wall from heat, or an acceptable alternative to the listed backguard sold by Thermador for the specific appliance. The listed stainless steel backguard has an air gap behind it to dissipate the heat.

(PDF) A Review of Pathways for Building Fire Spread in the ...

(OSB, 1.27 cm gypsum board, weather wrap, and vinyl siding) Burning adjacent . structure, nominal . peak heat release . rate (HRR)15 MW. Radiant heat flux . nominally 30 . kW/m 2.

FIBEROCK Tile Backerboard vs HardieBacker Cement Board ...

Residential Building Code everywhere requires no white gypsum wall board or green board - but rather a tile backer board made specifically for that purpose. Schluter does have a evaluation report that you can copy and take to the local building official and see if they accept it or not - then get their approval in writing before hanging your ...

finishing - Home Improvement Stack Exchange

Blob on golf ball sized portions of glue on an approx. 16"X16" grid. Set your drywall onto that and secure directly into the block with drywall nails. that is if they pass the test. To test your nails drive a few drywall nails into the face of the block before you start your drywall install. Do not nail in the joints, the mortar is much denser.

insulation - What is the minimum thickness of foam board ...

The product you reference is 1/4" thick and only rated R-1 per board. So you would need ten sheets of this product to reach R-10. It would be much more cost-effective to buy a single 2 or 3" board. I believe Home Depot sells 1-3" …

(PDF) Firefighter Product and Systems Awarness

gypsum board are discussed. It offers key fact s on why gypsum board is the most commonly used . material to deter fire spread. As well, ...

Insulating Existing Garage with Polyiso Foam Board | DIY ...

Any foam board should be covered with gypsum board to protect the foam from heat/flames. You do not state whether your studs are 2x4 or 2x6. R-19 fiberglass insulation was originally designed for 2x8 floor systems. When used in a 2x6 wall assembly it is actually compressed and will provide about R16.7.

Cashmere, WA | Home

protected on the underside by 1/2" gypsum board, or 5/8" structural wood sheathing. or greater dimensional lumber and composite lumber are exempt. Crawl spaces with storage or fuel-fired appliances are subject to the requirements. R602.12 — Simplified Wall Bracing A new section provides a "cook book" methodology for wall bracing.

Resin Panel Wall · Issue #52 · OpeningDesign/Sports ...

Proposal 1: (Instead of plywood on these exterior walls, I would like to propose using exterior gypsum board instead. From my understanding, if we satisfy exception 717.2.6.2.3 and use Gyp. Bd., which is noncombustible, we do not …

Drywall, 1/2 or 5/8 on garage separation? | The Building ...

Type X gypsum board for garage ceilings beneath habitable rooms shall be installed perpendicular to the ceiling framing and shall be fastened at maximum 6 inches o.c. by minimum 17/8 inches 6d coated nails or equivalent drywall screws.

TCNA shower guidline help [Archive ... - John Bridge

Water-resistant gypsum backing board shall be used as a base for tile in water closet compartment walls when installed in accordance with GA-216 or ASTM C 840 and manufacturer recommendations. Regular gypsum wallboard is permitted under tile or wall panels in other wall and ceiling areas when installed in accordance with GA-216 or ASTM C 840.

Basement: Rigid Foam + Framing - DIY Home …

1/2 - inch gypsum board 2x lumber (2x4, 2x6, etc.). Two thicknesses of 1x lumber (1x4, 1x6, etc.) with staggered joints. 3/4 - inch plywood 1/4 - inch cement, cement/fiber board (e.g., Durock) At gaps 1 inch or less, batts or blankets of mineral wool or fiberglass pack tightly or approved fireblocking caulk

AIA Minnesota

Gypsum board having a minimum thickness of 1/2 inch (12.7 mm) provided all joints have continuous support. Sheet steel not less than 26 ga (0.38 mm) thickness provided all joints have continuous support. Cement-based millboard having a minimum thickness of 1/4 -inch (6.4 mm). Batts or blankets of mineral wool, mineral fiber or other approved

2x6 Wall w/ 2" Exterior XPS/EPS in South - GreenBuildingTalk

Metel, 2x4 purlins, attic trusses filled with 10"+ of dense packed cellulose, 1/2" gypsum board. Another idea might be to use 2" of xps instead of osb. In this idea the 2x4 purlins would basically hold down the xps and give something for the metel to hold to.

Vertical vs Horizontal drywall | Page 2 | DIY Home ...

Gypsum sheathing shall be attached to exterior walls in accordance with Table R602.3(1). Gypsum board shall be applied at right angles or parallel to framing members. All edges and ends of gypsum board shall occur on the framing members, except those edges and ends that are perpendicular to the framing members.

Construction Concerns: Wood Frame Concealed Spaces

Gypsum drywall board is installed on the wood studs to a point a few inches above the height of the suspended ceiling that will be installed in smaller rooms (offices, break rooms, washrooms, and corridors). The space between these studs above the suspended ceiling may be filled with sound-deadening insulation or may be left open.

epoxycoat | Page 2 | DIY Home Improvement Forum

(typically Type X gypsum board) between building sections such as the garage and habitable space. Traditionally, exposed floor or ceiling framing has been allowed in unrated construction. But according to the 2012 International Residential Code (IRC), an exposed floor or ceiling framing system may require protection. Section R501.3

Architectural_Detailing_Function,_Constructibilit_2696469 ...

Chicago: PCI, 2001. (This is a complete guide to designing semblies, using both plaster and gypsum board.) GFRC cladding.) 3. *National Association of Architectural Metal Manufactur-10. Schittich, Christian. Glass Construction Manual. Basel, Swit- ers. Recommended Selection and Usage Guide for Hollow zerland: Birkhauser, 2007.

IMC 602.2.1 Exception #5 - The Building Code Forum

Sep 30, 2015. #2. 602.1 General. Supply, return, exhaust, relief and ventilation air plenums shall be limited to uninhabited crawl spaces, areas above a ceiling or below the floor, attic spaces and mechanical equipment rooms. Plenums shall be limited to one fire area.

2018 INTERNATIONAL BUILDING CODE (IBC) | ICC DIGITAL …

Chapter 25 Gypsum Board, Gypsum Panel Products and Plaster. Chapter 25 contains the provisions and referenced standards that regulate the design, construction and quality of gypsum board, gypsum panel products and plaster. It also addresses reinforced gypsum concrete. These represent the most common interior and exterior finish materials in the ...

Architekturexport - wwnaxldb.bak-ssl.de

110.3.5 Lath and gypsum board inspection. Lath and gypsum board inspections shall be made after lathing and gypsum board, interior and exterior, is in place, but before any plastering is applied or gypsum board joints and fasteners are taped and finished. Exception: Gypsum board that is not part of a fire-resistance-rated assembly or a shear ...

Mark Bartel, P.E., Technical Director International Beams ...

1. ½ inch thick gypsum board ceiling over basement 2. Partial sprinkler system (ceiling over basement only) 3. Field-applied fire-retardant paint (applied to I-joists, subfloor and rimboard) 4. ½ inch thick gypsum board cladding per APA report ESR-1405 (either full-height fastened to the flanges or fastened to OSB webs only)

Code 3Check Building

Gb Gypsum Board hr hour ibC International Building Code L&L Listed & Labeled LL Lot Line max maximum min minimum mph miles per hour o.c. on center Pt Pressure Treated psf pounds per square foot psi pounds per square inch req require req'd req'd req's requires, requirements sDC Seismic Design Category sDC D SDC D 0, D 1, & D 2 UL ...